FUJITSU SEMICONDUCTOR DATA SHEET
DS05-20858-4E
FLASH MEMORY
CMOS
8M (1M x 8) BIT
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
s FEATURES
* Single 3.0 V read, program, and erase Minimizes system level power requirements * Compatible with JEDEC-standard commands Uses same software commands as E2PROMs * Compatible with JEDEC-standard world-wide pinouts 40-pin TSOP(I) (Package suffix: PTN - Normal Bend Type, PTR - Reversed Bend Type) * Minimum 100,000 program/erase cycles * High performance 70 ns maximum access time * Sector erase architecture One 16K byte, two 8K bytes, one 32K byte, and fifteen 64K bytes Any combination of sectors can be concurrently erased. Also supports full chip erase * Boot Code Sector Architecture T = Top sector B = Bottom sector * Embedded EraseTM Algorithms Automatically pre-programs and erases the chip or any sector * Embedded ProgramTM Algorithms Automatically writes and verifies data at specified address * Data Polling and Toggle Bit feature for detection of program or erase cycle completion * Ready/Busy output (RY/BY) Hardware method for detection of program or erase cycle completion * Automatic sleep mode When addresses remain stable, automatically switch themselves to low power mode * Low VCC write inhibit 2.5 V * Erase Suspend/Resume Suspends the erase operation to allow a read data in another sector within the same device * Sector protection Hardware method disables any combination of sectors from program or erase operations * Sector Protection Set function by Extended sector protection command * Temporary sector unprotection Temporary sector unprotection via the RESET pin
Embedded EraseTM and Embedded ProgramTM are trademarks of Advanced Micro Devices, Inc.
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
s PACKAGE
40-pin plastic TSOP (I)
Marking Side
40-pin plastic TSOP (I)
Marking Side
(FPT-40P-M06)
(FPT-40P-M07)
2
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
s GENERAL DESCRIPTION
The MBM29LV008TA/BA are a 8M-bit, 3.0 V-only Flash memory organized as 1M bytes of 8 bits each. The MBM29LV008TA/BA are offered in a 40-pin TSOP(I) package. These devices are designed to be programmed in-system with the standard system 3.0 V VCC supply. 12.0 V VPP and 5.0 V VCC are not required for write or erase operations. The devices can also be reprogrammed in standard EPROM programmers. The standard MBM29LV008TA/BA offer access times 70 ns and 120 ns, allowing operation of high-speed microprocessors without wait states. To eliminate bus contention the devices have separate chip enable (CE), write enable (WE), and output enable (OE) controls. The MBM29LV008TA/BA are pin and command set compatible with JEDEC standard E2PROMs. Commands are written to the command register using standard microprocessor write timings. Register contents serve as input to an internal state-machine which controls the erase and programming circuitry. Write cycles also internally latch addresses and data needed for the programming and erase operations. Reading data out of the devices is similar to reading from 5.0 V and 12.0 V Flash or EPROM devices. The MBM29LV008TA/BA are programmed by executing the program command sequence. This will invoke the Embedded Program Algorithm which is an internal algorithm that automatically times the program pulse widths and verifies proper cell margin. Typically, each sector can be programmed and verified in about 0.5 seconds. Erase is accomplished by executing the erase command sequence. This will invoke the Embedded Erase Algorithm which is an internal algorithm that automatically preprograms the array if it is not already programmed before executing the erase operation. During erase, the devices automatically time the erase pulse widths and verify proper cell margin. Any individual sector is typically erased and verified in 1.0 second. (If already completely preprogrammed.) The devices also feature a sector erase architecture. The sector mode allows each sector to be erased and reprogrammed without affecting other sectors. The MBM29LV008TA/BA are erased when shipped from the factory. The devices feature single 3.0 V power supply operation for both read and write functions. Internally generated and regulated voltages are provided for the program and erase operations. A low VCC detector automatically inhibits write operations on the loss of power. The end of program or erase is detected by Data Polling of DQ7, by the Toggle Bit feature on DQ6, or the RY/BY output pin. Once the end of a program or erase cycle has been completed, the devices internally reset to the read mode. Fujitsu's Flash technology combines years of EPROM and E2PROM experience to produce the highest levels of quality, reliability, and cost effectiveness. The MBM29LV008TA/BA memories electrically erase the entire chip or all bits within a sector simultaneously via Fowler-Nordhiem tunneling. The bytes are programmed one byte at a time using the EPROM programming mechanism of hot electron injection.
3
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
s FLEXIBLE SECTOR-ERASE ARCHITECTURE
* One 16K byte, two 8K bytes, one 32K byte, and fifteen 64K bytes * Individual-sector, multiple-sector, or bulk-erase capability * Individual or multiple-sector protection is user definable.
FFFFFH 16K byte FC000H 8K byte FA000H 8K byte F8000H 32K byte F0000H 64K byte E0000H 64K byte D0000H 64K byte C0000H 64K byte B0000H 64K byte A0000H 64K byte 90000H 64K byte 80000H 64K byte 70000H 64K byte 60000H 64K byte 50000H 64K byte 40000H 64K byte 30000H 64K byte 20000H 64K byte 10000H 64K byte 00000H MBM29LV008TA Sector Architecture 16K byte 8K byte 8K byte 32K byte 64K byte 64K byte 64K byte 64K byte 64K byte 64K byte 64K byte 64K byte 64K byte 64K byte 64K byte 64K byte 64K byte 64K byte 64K byte
FFFFFH F0000H E0000H D0000H C0000H B0000H A0000H 90000H 80000H 70000H 60000H 50000H 40000H 30000H 20000H 10000H 08000H 06000H 04000H 00000H MBM29LV008BA Sector Architecture
4
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
s PRODUCT LINE UP
Part No. VCC = 3.3 V Ordering Part No. VCC = 3.0 V Max. Address Access Time (ns) Max. CE Access Time (ns) Max. OE Access Time (ns)
+0.3 V -0.3 V +0.6 V -0.3 V
MBM29LV008TA/MBM29LV008BA -70 -- 70 70 30 -- -90 90 90 35 -- -12 120 120 50
s BLOCK DIAGRAM
RY/BY Buffer VCC VSS
DQ 0 to DQ 7 RY/BY
Erase Voltage Generator
Input/Output Buffers
WE State Control RESET Command Register Program Voltage Generator CE OE Chip Enable Output Enable Logic STB Data Latch
STB
Y-Decoder
Y-Gating
Low VCC Detector
Timer for Program/Erase
Address Latch
X-Decoder
Cell Matrix
A0 to A19
5
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
s CONNECTION DIAGRAMS
TSOP (I) A16 A15 A14 A13 A12 A11 A9 A8 WE RESET N.C. RY/BY A18 A7 A6 A5 A4 A3 A2 A1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
(Marking Side)
MBM29LV008TA/MBM29LV008BA Standard Pinout
40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21
A17 VSS N.C. A19 A10 DQ7 DQ6 DQ5 DQ4 VCC VCC N.C. DQ3 DQ2 DQ1 DQ0 OE VSS CE A0
FPT-40P-M06
A1 A2 A3 A4 A5 A6 A7 A18 RY/BY N.C. RESET WE A8 A9 A11 A12 A13 A14 A15 A16
20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(Marking Side)
MBM29LV008TA/MBM29LV008BA Reverse Pinout
21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
A0 CE VSS OE DQ0 DQ1 DQ2 DQ3 N.C. VCC VCC DQ4 DQ5 DQ6 DQ7 A10 A19 N.C. VSS A17
FPT-40P-M07
6
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
s LOGIC SYMBOL
Table 1 Pin A0 to A19
20 A0 to A19 DQ 0 to DQ 7 8
MBM29LV008TA/008BA Pin Configuration Function Address Inputs Data Inputs/Outputs Chip Enable Output Enable Write Enable Ready/Busy Output Hardware Reset Pin/Temporary Sector Unprotection No Internal Connection Device Ground Device Power Supply
DQ0 to DQ7 CE OE
CE OE WE RESET RY/BY
WE RY/BY RESET N.C. VSS VCC Table 2
MBM29LV008TA/008BA User Bus Operations CE L L L H L L L L X X OE L L L X H H VID L X X H X X WE H H H X H L A0 L H A0 X X A0 L L X X A1 L L A1 X X A1 H H X X A6 L L A6 X X A6 L L X X A9 VID VID A9 X X A9 VID VID X X A10 L L A10 X X A10 X L X X
DQ0 to DQ7 RESET
Operation Auto-Select Manufacturer Code (1) Auto-Select Device Code (1) Read (3) Standby Output Disable Write (Program/Erase) Enable Sector Protection (2), (4) Verify Sector Protection (2), (4) Temporary Sector Unprotection (5) Reset (Hardware)/Standby
Code Code DOUT HIGH-Z HIGH-Z DIN X Code X HIGH-Z
H H H H H H H H VID L
Legend: L = VIL, H = VIH, X = VIL or VIH,
= Pulse input. See DC Characteristics for voltage levels.
Notes: 1. Manufacturer and device codes may also be accessed via a command register write sequence. See Table 6. 2. Refer to the section on Sector Protection. 3. WE can be VIL if OE is VIL, OE at VIH initiates the write operations. 4. VCC = 3.3 V 10% 5. It is also used for the extended sector protection.
7
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
s ORDERING INFORMATION
Standard Products
Fujitsu standard products are available in several packages. The order number is formed by a combination of:
MBM29LV008
T
A
-70
PTN
PACKAGE TYPE PTN = 40-Pin Thin Small Outline Package (TSOP) Standard Pinout PTR = 40-Pin Thin Small Outline Package (TSOP) Reverse Pinout SPEED OPTION See Product Selector Guide Device Revision BOOT CODE SECTOR ARCHITECTURE T = Top sector B = Bottom sector DEVICE NUMBER/DESCRIPTION MBM29LV008 8Mega-bit (1M x 8-Bit) CMOS Flash Memory 3.0 V-only Read, Program, and Erase
8
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
s FUNCTIONAL DESCRIPTION
Read Mode
The MBM29LV008TA/BA have two control functions which must be satisfied in order to obtain data at the outputs. CE is the power control and should be used for a device selection. OE is the output control and should be used to gate data to the output pins if a device is selected. Address access time (tACC) is equal to the delay from stable addresses to valid output data. The chip enable access time (tCE) is the delay from stable addresses and stable CE to valid data at the output pins. The output enable access time is the delay from the falling edge of OE to valid data at the output pins. (Assuming the addresses have been stable for at least tACC-tOE time.) When reading out a data without changing addresses after power-up, it is necessary to input hardware reset or change CE pin from "H" or "L"
Standby Mode
There are two ways to implement the standby mode on the MBM29LV008TA/BA devices, one using both the CE and RESET pins; the other via the RESET pin only. When using both pins, a CMOS standby mode is achieved with CE and RESET inputs both held at VCC 0.3 V. Under this condition the current consumed is less than 5 A. The device can be read with standard access time (tCE) from either of these standby modes. During Embedded Algorithm operation, VCC active current (ICC2) is required even CE = "H". When using the RESET pin only, a CMOS standby mode is achieved with RESET input held at VSS 0.3 V (CE = "H" or "L"). Under this condition the current is consumed is less than 5 A. Once the RESET pin is taken high, the device requires tRH of wake up time before outputs are valid for read access. In the standby mode the outputs are in the high impedance state, independent of the OE input.
Automatic Sleep Mode
There is a function called automatic sleep mode to restrain power consumption during read-out of MBM29LV008TA/BA data. This mode can be used effectively with an application requested low power consumption such as handy terminals. To activate this mode, MBM29LV008TA/BA automatically switch themselves to low power mode when MBM29LV008TA/BA addresses remain stably during access fine of 150 ns. It is not necessary to control CE, WE, and OE on the mode. Under the mode, the current consumed is typically 1 A (CMOS Level). Since the data are latched during this mode, the data are read-out continuously. If the addresses are changed, the mode is canceled automatically and MBM29LV008TA/BA read-out the data for changed addresses.
Output Disable
With the OE input at a logic high level (VIH), output from the devices are disabled. This will cause the output pins to be in a high impedance state.
Autoselect
The autoselect mode allows the reading out of a binary code from the devices and will identify its manufacturer and type. This mode is intended for use by programming equipment for the purpose of automatically matching the devices to be programmed with its corresponding programming algorithm. This mode is functional over the entire temperature range of the devices. To activate this mode, the programming equipment must force VID (11.5 V to 12.5 V) on address pin A9. Two identifier bytes may then be sequenced from the devices outputs by toggling address A0 from VIL to VIH. All addresses are DON'T CARES except A0, A1, A6, and A10. (See Table 3.1.)
9
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
The manufacturer and device codes may also be read via the command register, for instances when the MBM29LV008TA/BA are erased or programmed in a system without access to high voltage on the A9 pin. The command sequence is illustrated in Table 6. (Refer to Autoselect Command section.) Byte 0 (A0 = VIL) represents the manufacturer's code (Fujitsu = 04H) and (A0 = VIH) represents the device identifier code (MBM29LV008TA = 3EH and MBM29LV008BA = 37H). These two bytes/words are given in the tables 3.1 and 3.2. All identifiers for manufactures and device will exhibit odd parity with DQ7 defined as the parity bit. In order to read the proper device codes when executing the autoselect, A1 must be VIL. (See Tables 3.1 and 3.2.) Table 3 .1 MBM29LV008TA/008BA Sector Protection Verify Autoselect Codes Type Manufacture's Code MBM29LV008TA Device Code MBM29LV008BA Sector Protection X Sector Addresses VIL VIL VIL VIL VIL VIH VIH VIL 37H 01H* A13 to A19 X X A10 VIL VIL A6 VIL VIL A1 VIL VIL A0 VIL VIH Code (HEX) 04H 3EH
* : Outputs 01H at protected sector addresses and outputs 00H at unprotected sector addresses. Table 3 .2 Expanded Autoselect Code Table Type Manufacture's Code MBM29LV008TA Device Code MBM29LV008BA Sector Protection 37H 01H 0 0 0 0 1 0 1 0 0 0 1 0 1 0 1 1 Code 04H 3EH DQ7 0 0 DQ6 0 0 DQ5 0 1 DQ4 0 1 DQ3 0 1 DQ2 1 1 DQ1 0 1 DQ0 0 0
10
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
Table 4 Sector Address SA0 SA1 SA2 SA3 SA4 SA5 SA6 SA7 SA8 SA9 SA10 SA11 SA12 SA13 SA14 SA15 SA16 SA17 SA18 A19 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 A18 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 1 1 1 Sector Address Tables (MBM29LV008TA) A16 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 1 1 1 A15 X X X X X X X X X X X X X X X 0 1 1 1 A14 X X X X X X X X X X X X X X X X 0 0 1 A13 X X X X X X X X X X X X X X X X 0 1 X Address Range 00000H to 0FFFFH 10000H to 1FFFFH 20000H to 2FFFFH 30000H to 3FFFFH 40000H to 4FFFFH 50000H to 5FFFFH 60000H to 6FFFFH 70000H to 7FFFFH 80000H to 8FFFFH 90000H to 9FFFFH A0000H to AFFFFH B0000H to BFFFFH C0000H to CFFFFH D0000H to DFFFFH E0000H to EFFFFH F0000H to F7FFFH F8000H to F9FFFH FA000H to FBFFFH FC000H to FFFFFH
A17 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 1 1 1
11
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
Write
Device erasure and programming are accomplished via the command register. The contents of the register serve as inputs to the internal state machine. The state machine outputs dictate the function of the device. The command register itself does not occupy any addressable memory location. The register is a latch used to store the commands, along with the address and data information needed to execute the command. The command register is written by bringing WE to VIL, while CE is at VIL and OE is at VIH. Addresses are latched on the falling edge of WE or CE, whichever happens later; while data is latched on the rising edge of WE or CE, whichever happens first. Standard microprocessor write timings are used. Refer to AC Write Characteristics and the Erase/Programming Waveforms for specific timing parameters.
Sector Protection
The MBM29LV008TA/BA feature hardware sector protection. This feature will disable both program and erase operations in any number of sectors (0 through 18). The sector protection feature is enabled using programming equipment at the user's site. The devices are shipped with all sectors unprotected. Alternatively, Fujitsu may program and protect sectors in the factory prior to shiping the device. To activate this mode, the programming equipment must force VID on address pin A9 and control pin OE, (suggest VID = 11.5 V), CE = VIL, and A6 = VIL. The sector addresses (A19, A18, A17, A16, A15, A14, and A13) should be set to the sector to be protected. Tables 4 and 5 define the sector address for each of the nineteen (19) individual sectors. Programming of the protection circuitry begins on the falling edge of the WE pulse and is terminated with the rising edge of the same. Sector addresses must be held constant during the WE pulse. See Figures 13 and 21 for sector protection waveforms and algorithm. To verify programming of the protection circuitry, the programming equipment must force VID on address pin A9 with CE and OE at VIL and WE at VIH. Scanning the sector addresses (A19, A18, A17, A16, A15, A14, and A13) while (A10, A6, A1, A0) = (0, 0, 1, 0) will produce a logical "1" code at device output DQ0 for a protected sector. Otherwise the devices will read 00H for unprotected sector. In this mode, the lower order addresses, except for A0, A1, A6, and A10 are DON'T CARES. Address locations with A1 = VIL are reserved for Autoselect manufacturer and device codes. It is also possible to determine if a sector is protected in the system by writing an Autoselect command. Performing a read operation at the address location XX02H, where the higher order addresses (A19, A18, A17, A16, A15, A14, and A13) are the desired sector address will produce a logical "1" at DQ0 for a protected sector. See Tables 3.1 and 3.2 for Autoselect codes.
Temporary Sector Unprotection
This feature allows temporary unprotection of previously protected sectors of the MBM29LV008TA/BA devices in order to change data. The Sector Unprotection mode is activated by setting the RESET pin to high voltage (12 V). During this mode, formerly protected sectors can be programmed or erased by selecting the sector addresses. Once the 12 V is taken away from the RESET pin, all the previously protected sectors will be protected again. See Figures 14 and 22.
12
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
Table 5 Sector Address SA0 SA1 SA2 SA3 SA4 SA5 SA6 SA7 SA8 SA9 SA10 SA11 SA12 SA13 SA14 SA15 SA16 SA17 SA18 A19 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 A18 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 Sector Address Tables (MBM29LV008BA) A16 0 0 0 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 A15 0 0 0 1 X X X X X X X X X X X X X X X A14 0 1 1 X X X X X X X X X X X X X X X X A13 X 0 1 X X X X X X X X X X X X X X X X Address Range 00000H to 03FFFH 04000H to 05FFFH 06000H to 07FFFH 08000H to 0FFFFH 10000H to 1FFFFH 20000H to 2FFFFH 30000H to 3FFFFH 40000H to 4FFFFH 50000H to 5FFFFH 60000H to 6FFFFH 70000H to 7FFFFH 80000H to 8FFFFH 90000H to 9FFFFH A0000H to AFFFFH B0000H to BFFFFH C0000H to CFFFFH D0000H to DFFFFH E0000H to EFFFFH F0000H to FFFFFH
A17 0 0 0 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1
13
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
Table 6 MBM29LV008TA/008BA Standard Command Definitions
Command Sequence Read/Reset Read/Reset Autoselect Program Chip Erase Sector Erase
First Bus Second Bus Third Bus Fourth Bus Fifth Bus Sixth Bus Bus Read/Write Write Cycle Write Cycle Write Write Cycle Write Cycle Write Cycle Cycle Cycles Req'd Addr. Data Addr. Data Addr. Data Addr. Data Addr. Data Addr. Data 1 3 3 4 6 6 XXXH F0H 555H AAH 555H AAH 555H AAH 555H AAH 555H AAH -- 2AAH 2AAH 2AAH 2AAH 2AAH -- 55H 55H 55H 55H 55H -- 555H 555H 555H 555H 555H -- F0H 90H A0H 80H 80H -- RA -- PA -- RD -- PD -- -- -- -- 2AAH 2AAH -- -- -- -- 55H 55H -- -- -- -- 555H SA -- -- -- -- 10H 30H
555H AAH 555H AAH
Sector Erase Suspend Sector Erase Resume
Erase can be suspended during sector erase with Addr. ("H" or "L"). Data (B0H) Erase can be resumed after suspend with Addr. ("H" or "L"). Data (30H)
Notes: 1. Address bits A11 to A19 = X = "H" or "L" for all address commands except or Program Address (PA) and Sector Address (SA) 2. Bus operations are defined in Table 2. 3. RA = Address of the memory location to be read PA = Address of the memory location to be programmed Addresses are latched on the falling edge of the write pulse. SA = Address of the sector to be erased. The combination of A19, A18, A17, A16, A15, A14, and A13 will uniquely select any sector. 4. RD = Data read from location RA during read operation. PD = Data to be programmed at location PA. Data is latched on the falling edge of write pulse. 5. Both Read/Reset commands are functionally equivalent, resetting the device to the read mode.
14
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
Table 7 Command Sequence Set to Fast Mode Fast Program *1 Reset from Fast Mode *1 Extended Sector Protect * 2 Bus Write Cycles Req'd 3 2 2 4 MBM29LV008TA/BA Extended Command Definitions First Bus Write Cycle Addr 555H XXXH XXXH XXXH Data AAH A0H 90H 60H Second Bus Write Cycle Addr 2AAH PA XXXH SPA Data 55H PD F0H *3 60H Third Bus Write Cycle Addr 555H -- -- SPA Data 20H -- -- 40H Fourth Bus Read Cycle Addr -- -- -- SPA Data -- -- -- SD
SPA: Sector address to be protected. Set sector address (SA) and (A10, A6, A1, A0) = (0, 0, 1, 0). SD: Sector protection verify data. Output 01H at protected sector addresses and output 00H at unprotected sector addresses. *1: This command is valid while Fast Mode. *2: This command is valid while RESET= VID. *3: The data "00H" is also acceptable.
Command Definitions
Device operations are selected by writing specific address and data sequences into the command register. Writing incorrect address and data values or writing them in the improper sequence will reset the devices to the read mode. Table 6 defines the valid register command sequences. Note that the Erase Suspend (B0H) and Erase Resume (30H) commands are valid only while the Sector Erase operation is in progress. Moreover both Read/Reset commands are functionally equivalent, resetting the device to the read mode.
Read/Reset Command
In order to return from Autoselect mode or Exceeded Timing Limits (DQ5 = 1) to read/reset mode, the read/reset operation is initiated by writing the Read/Reset command sequence into the command register. Microprocessor read cycles retrieve array data from the memory. The devices remain enabled for reads until the command register contents are altered. The devices will automatically power-up in the read/reset state. In this case, a command sequence is not required to read data. Standard microprocessor read cycles will retrieve array data. This default value ensures that no spurious alteration of the memory content occurs during the power transition. Refer to the AC Read Characteristics and Waveforms for the specific timing parameters.
15
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
Autoselect Command
Flash memories are intended for use in applications where the local CPU alters memory contents. As such, manufacture and device codes must be accessible while the devices reside in the target system. PROM programmers typically access the signature codes by raising A9 to a high voltage. However, multiplexing high voltage onto the address lines is not generally desired system design practice. The device contains an Autoselect command operation to supplement traditional PROM programming methodology. The operation is initiated by writing the Autoselect command sequence into the command register. Following the command write, a read cycle from address XX00H retrieves the manufacture code of 04H. A read cycle from address XX01H returns the device code (MBM29LV008TA = 3EH and MBM29LV008BA = 37H). (See Tables 3.1 and 3.2.) All manufacturer and device codes will exhibit odd parity with DQ7 defined as the parity bit. Sector state (protection or unprotection) will be informed by address XX02H. Scanning the sector addresses (A19, A18, A17, A16, A15, A14, and A13) while (A10, A6, A1, A0) = (0, 0, 1, 0) will produce a logical "1" at device output DQ0 for a protected sector. The programming verification should be perform margin mode on the protected sector. (See Tables 2 and 3.) To terminate the operation, it is necessary to write the Read/Reset command sequence into the register, and also to write the Autoselect command during the operation, execute it after writing Read/Reset command sequence.
Byte Programming
The devices are programmed on a byte-by-byte basis. Programming is a four bus cycle operation. There are two "unlock" write cycles. These are followed by the program set-up command and data write cycles. Addresses are latched on the falling edge of CE or WE, whichever happens later and the data is latched on the rising edge of CE or WE, whichever happens first. The rising edge of CE or WE (whichever happens first) begins programming. Upon executing the Embedded Program Algorithm command sequence, the system is not required to provide further controls or timings. The device will automatically provide adequate internally generated program pulses and verify the programmed cell margin. The automatic programming operation is completed when the data on DQ7 is equivalent to data written to this bit at which time the devices return to the read mode and addresses are no longer latched. (See Table 8, Hardware Sequence Flags.) Therefore, the devices require that a valid address to the devices be supplied by the system at this particular instance of time. Hence, Data Polling must be performed at the memory location which is being programmed. Any commands written to the chip during this period will be ignored. If hardware reset occurs during the programming operation, it is impossible to guarantee the data are being written. Programming is allowed in any sequence and across sector boundaries. Beware that a data "0" cannot be programmed back to a "1". Attempting to do so may either hang up the device or result in an apparent success according to the data polling algorithm but a read from read/reset mode will show that the data is still "0". Only erase operations can convert "0"s to "1"s. Figure 17 illustrates the Embedded ProgramTM Algorithm using typical command strings and bus operations.
16
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
Chip Erase
Chip erase is a six bus cycle operation. There are two "unlock" write cycles. These are followed by writing the "set-up" command. Two more "unlock" write cycles are then followed by the chip erase command. Chip erase does not require the user to program the device prior to erase. Upon executing the Embedded Erase Algorithm command sequence the devices will automatically program and verify the entire memory for an all zero data pattern prior to electrical erase (Preprogram function). The system is not required to provide any controls or timings during these operations. The automatic erase begins on the rising edge of the last write pulse in the command sequence and terminates when the data on DQ7 is "1" (See Write Operation Status section.) at which time the device returns to read the mode. Chip Erase Time; Sector Erase Time x All sectors + Chip Program Time (Preprogramming) Figure 18 illustrates the Embedded EraseTM Algorithm using typical command strings and bus operations.
Sector Erase
Sector erase is a six bus cycle operation. There are two "unlock" write cycles. These are followed by writing the "set-up" command. Two more "unlock" write cycles are then followed by the Sector Erase command. The sector address (any address location within the desired sector) is latched on the falling edge of write pulse, while the command (Data=30H) is latched on the rising edge of write pulse. After time-out of 50 s from the rising edge of the last sector erase command, the sector erase operation will begin. Multiple sectors may be erased concurrently by writing the six bus cycle operations on Table 6. This sequence is followed with writes of the Sector Erase command to addresses in other sectors desired to be concurrently erased. The time between writes must be less than 50 s otherwise that command will not be accepted and erasure will start. It is recommended that processor interrupts be disabled during this time to guarantee this condition. The interrupts can be re-enabled after the last Sector Erase command is written. A time-out of 50 s from the rising edge of the last write pulse will initiate the execution of the Sector Erase command(s). If another falling edge of the write pulse occurs within the 50 s time-out window the timer is reset. (Monitor DQ3 to determine if the sector erase timer window is still open, see section DQ3, Sector Erase Timer.) Any command other than Sector Erase or Erase Suspend during this time-out period will reset the devices to the read mode, ignoring the previous command string. Resetting the devices once execution has begun will corrupt the data in the sector. In that case, restart the erase on those sectors and allow them to complete. (Refer to the Write Operation Status section for Sector Erase Timer operation.) Loading the sector erase buffer may be done in any sequence and with any number of sectors (0 to 18). Sector erase does not require the user to program the devices prior to erase. The devices automatically program all memory locations in the sector(s) to be erased prior to electrical erase (Preprogram function). When erasing a sector or sectors the remaining unselected sectors are not affected. The system is not required to provide any controls or timings during these operations. The automatic sector erase begins after the 50 s time out from the rising edge of the write pulse pulse for the last sector erase command pulse and terminates when the data on DQ7 is "1" (See Write Operation Status section.) at which time the devices return to the read mode. Data polling must be performed at an address within any of the sectors being erased. Multiple Sector Erase Time; [Sector Erase Time + Sector Program Time (Preprogramming)] x Number of Sector Erase Figure 18 illustrates the Embedded EraseTM Algorithm using typical command strings and bus operations.
17
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
Erase Suspend
The Erase Suspend command allows the user to interrupt a Sector Erase operation and then perform data reads from or programs to a sector not being erased. This command is applicable ONLY during the Sector Erase operation which includes the time-out period for sector erase. The Erase Suspend command will be ignored if written during the Chip Erase operation or Embedded Program Algorithm. Writting the Erase Suspend command during the Sector Erase time-out results in immediate termination of the time-out period and suspension of the erase operation. Writing the Erase Resume command resumes the erase operation. The addresses are DON'T CARES when writing the Erase Suspend or Erase Resume command. When the Erase Suspend command is written during the Sector Erase operation, the device will take a maximum of 20 s to suspend the erase operation. When the devices have entered the erase-suspended mode, the RY/ BY output pin and the DQ7 bit will be at logic "1", and DQ6 will stop toggling. The user must use the address of the erasing sector for reading DQ6 and DQ7 to determine if the erase operation has been suspended. Further writes of the Erase Suspend command are ignored. When the erase operation has been suspended, the devices default to the erase-suspend-read mode. Reading data in this mode is the same as reading from the standard read mode except that the data must be read from sectors that have not been erase-suspended. Successively reading from the erase-suspended sector while the device is in the erase-suspend-read mode will cause DQ2 to toggle. (See the section on DQ2.) After entering the erase-suspend-read mode, the user can program the device by writing the appropriate command sequence for Program. This program mode is known as the erase-suspend-program mode. Again, programming in this mode is the same as programming in the regular Program mode except that the data must be programmed to sectors that are not erase-suspended. Successively reading from the erase-suspended sector while the devices are in the erase-suspend-program mode will cause DQ2 to toggle. The end of the erasesuspended Program operation is detected by the RY/BY output pin, Data polling of DQ7, or by the Toggle Bit I (DQ6) which is the same as the regular Program operation. Note that DQ7 must be read from the Program address while DQ6 can be read from any address. To resume the operation of Sector Erase, the Resume command (30H) should be written. Any further writes of the Resume command at this point will be ignored. Another Erase Suspend command can be written after the chip has resumed erasing.
18
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
Extended Command
(1) Fast Mode MBM29LV008TA/BA has Fast Mode function. This mode dispenses with the initial two unclock cycles required in the standard program command sequence by writing Fast Mode command into the command register. In this mode, the required bus cycle for programming is two cycles instead of four bus cycles in standard program command. (Do not write erase command in this mode.) The read operation is also executed after exiting this mode. To exit this mode, it is necessary to write Fast Mode Reset command into the command register. (Refer to the Figure 24 Extended algorithm.) The VCC active current is required even CE = VIH during Fast Mode. (2) Fast Programming During Fast Mode, the programming can be executed with two bus cycles operation. The Embedded Program Algorithm is executed by writing program set-up command (A0H) and data write cycles (PA/PD). (Refer to the Figure 24 Extended algorithm.) (3) Extended Sector Protection In addition to normal sector protection, the MBM29LV008TA/BA has Extended Sector Protection as extended function. This function enable to protect sector by forcing VID on RESET pin and write a commnad sequence. Unlike conventional procedure, it is not necessary to force VID and control timing for control pins. The only RESET pin requires VID for sector protection in this mode. The extended sector protect requires VID on RESET pin. With this condition, the operation is initiated by writing the set-up command (60H) into the command register. Then, the sector addresses pins (A19, A18, A17, A16, A15, A14, and A13) and (A10, A6, A1, A0) = (0, 0, 1, 0) should be set to the sector to be protected (recommend to set VIL for the other addresses pins), and write extended sector protect command (60H). A sector is typically protected in 150 s. To verify programming of the protection circuitry, the sector addresses pins (A19, A18, A17, A16, A15, A14, and A13) and (A10, A6, A1, A0) = (0, 0, 1, 0) should be set and write a command (40H). Following the command write, a logical "1" at device output DQ0 will produce for protected sector in the read operation. If the output data is logical "0", please repeat to write extended sector protect command (60H) again. To terminate the operation, it is necessary to set RESET pin to VIH.
19
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
Write Operation Status
Table 8 Status Embedded Program Algorithm Embedded Erase Algorithm In Progress Erase Suspend Read (Erase Suspended Sector) Erase Erase Suspend Read Suspended (Non-Erase Suspended Sector) Mode Erase Suspend Program (Non-Erase Suspended Sector) Embedded Program Algorithm Embedded Erase Algorithm Exceeded Time Limits Erase Erase Suspend Program Suspended (Non-Erase Suspended Sector) Mode Hardware Sequence Flags DQ7 DQ7 0 1 Data DQ7 DQ7 0 DQ7 DQ6 Toggle Toggle 1 Data Toggle (Note 1) Toggle Toggle Toggle DQ5 0 0 0 DQ3 0 1 0 DQ2 1 Toggle Toggle Data 1 (Note 2) 1 N/A N/A
Data Data 0 1 1 1 0 0 1 0
Notes: 1. Performing successive read operations from any address will cause DQ6 to toggle. 2. Reading the byte address being programmed while in the erase-suspend program mode will indicate logic "1" at the DQ2 bit. However, successive reads from the erase-suspended sector will cause DQ2 to toggle. 3. DQ0 and DQ1 are reserve pins for future use. 4. DQ4 is Fujitsu internal use only.
20
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
DQ7 Data Polling
The MBM29LV008TA/BA devices feature Data Polling as a method to indicate to the host that the Embedded Algorithms are in progress or completed. During the Embedded Program Algorithm an attempt to read the devices will produce the complement of the data last written to DQ7. Upon completion of the Embedded Program Algorithm, an attempt to read the device will produce the true data last written to DQ7. During the Embedded Erase Algorithm, an attempt to read the device will produce a "0" at the DQ7 output. Upon completion of the Embedded Erase Algorithm an attempt to read the device will produce a "1" at the DQ7 output. The flowchart for Data Polling (DQ7) is shown in Figure 19. For chip erase and sector erase, the Data Polling is valid after the rising edge of the sixth write pulse in the six write pulse sequence. Data Polling must be performed at sector address within any of the sectors being erased and not a protected sector. Otherwise, the status may not be valid. Once the Embedded Algorithm operation is close to being completed, the MBM29LV008TA/BA data pins (DQ7) may change asynchronously while the output enable (OE) is asserted low. This means that the devices are driving status information on DQ7 at one instant of time and then that byte's valid data at the next instant of time. Depending on when the system samples the DQ7 output, it may read the status or valid data. Even if the device has completed the Embedded Algorithm operation and DQ7 has a valid data, the data outputs on DQ0 to DQ6 may be still invalid. The valid data on DQ0 to DQ7 will be read on the successive read attempts. The Data Polling feature is only active during the Embedded Programming Algorithm, Embedded Erase Algorithm or sector erase time-out. (See Table 8.) See Figure 9 for the Data Polling timing specifications and diagrams.
DQ6 Toggle Bit I
The MBM29LV008TA/BA also feature the "Toggle Bit I" as a method to indicate to the host system that the Embedded Algorithms are in progress or completed. During an Embedded Program or Erase Algorithm cycle, successive attempts to read (OE toggling) data from the devices will result in DQ6 toggling between one and zero. Once the Embedded Program or Erase Algorithm cycle is completed, DQ6 will stop toggling and valid data will be read on the next successive attempts. During programming, the Toggle Bit I is valid after the rising edge of the fourth write pulse in the four write pulse sequence. For chip erase and sector erase, the Toggle Bit I is valid after the rising edge of the sixth write pulse in the six write pulse sequence. The Toggle Bit I is active during the sector time out. In programming, if the sector being written to is protected, the toggle bit will toggle for about 2 s and then stop toggling without the data having changed. In erase, the devices will erase all the selected sectors except for the ones that are protected. If all selected sectors are protected, the chip will toggle the toggle bit for about 100 s and then drop back into read mode, having changed none of the data. Either CE or OE toggling will cause the DQ6 to toggle. In addition, an Erase Suspend/Resume command will cause the DQ6 to toggle. See Figure 10 for the Toggle Bit I timing specifications and diagrams.
21
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
DQ5 Exceeded Timing Limits
DQ5 will indicate if the program or erase time has exceeded the specified limits (internal pulse count). Under these conditions DQ5 will produce a "1". This is a failure condition which indicates that the program or erase cycle was not successfully completed. Data Polling DQ7, DQ6 is the only operating function of the devices under this condition. The CE circuit will partially power down the device under these conditions (to approximately 2 mA). The OE and WE pins will control the output disable functions as described in Table 2. The DQ5 failure condition may also appear if a user tries to program a non blank location without erasing. In this case the devices lock out and never complete the Embedded Algorithm operation. Hence, the system never reads a valid data on DQ7 bit and DQ6 never stops toggling. Once the devices have exceeded timing limits, the DQ5 bit will indicate a "1." Please note that this is not a device failure condition since the devices were incorrectly used. If this occurs, reset the device with command sequence.
DQ3 Sector Erase Timer
After the completion of the initial sector erase command sequence the sector erase time-out will begin. DQ3 will remain low until the time-out is complete. Data Polling and Toggle Bit are valid after the initial sector erase command sequence. If Data Polling or the Toggle Bit I indicates the device has been written with a valid erase command, DQ3 may be used to determine if the sector erase timer window is still open. If DQ3 is high ("1") the internally controlled erase cycle has begun; attempts to write subsequent commands to the device will be ignored until the erase operation is completed as indicated by Data Polling or Toggle Bit I. If DQ3 is low ("0"), the device will accept additional sector erase commands. To insure the command has been accepted, the system software should check the status of DQ3 prior to and following each subsequent Sector Erase command. If DQ3 were high on the second status check, the command may not have been accepted. Refer to Table 8: Hardware Sequence Flags.
DQ2 Toggle Bit II
This Toggle bit II, along with DQ6, can be used to determine whether the devices are in the Embedded Erase Algorithm or in Erase Suspend. Successive reads from the erasing sector will cause DQ2 to toggle during the Embedded Erase Algorithm. If the devices are in the erase-suspended-read mode, successive reads from the erase-suspended sector will cause DQ2 to toggle. When the devices are in the erase-suspended-program mode, successive reads from the byte address of the non-erase suspended sector will indicate a logic "1" at the DQ2 bit. DQ6 is different from DQ2 in that DQ6 toggles only when the standard program or Erase, or Erase Suspend Program operation is in progress. The behavior of these two status bits, along with that of DQ7, is summarized as follows: For example, DQ2 and DQ6 can be used together to determine if the erase-suspend-read mode is in progress. (DQ2 toggles while DQ6 does not.) See also Table 8 and Figure 15. Furthermore, DQ2 can also be used to determine which sector is being erased. When the device is in the erase mode, DQ2 toggles if this bit is read from an erasing sector.
22
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
Mode Program Erase Erase-Suspend Read (Erase-Suspended Sector) (Note 1) Erase-Suspend Program
DQ7 DQ7 0 1 DQ7
DQ6 Toggle Toggle 1 Toggle (Note 1)
DQ2 1 Toggle Toggle 1 (Note 2)
Notes: 1. Performing successive read operations from any address will cause DQ6 to toggle. 2. Reading the byte address being programmed while in the erase-suspend program mode will indicate logic "1" at the DQ2 bit. However, successive reads from the erase-suspended sector will cause DQ2 to toggle.
RY/BY Ready/Busy
The MBM29LV008TA/BA provide a RY/BY open-drain output pin as a way to indicate to the host system that the Embedded Algorithms are either in progress or has been completed. If the output is low, the devices are busy with either a program or erase operation. If the output is high, the devices are ready to accept any read/write or erase operation. When the RY/BY pin is low, the devices will not accept any additional program or erase commands with the exception of the Erase Suspend command. If the MBM29LV008TA/BA are placed in an Erase Suspend mode, the RY/BY output will be high, by means of connecting with a pull-up resister to VCC. During programming, the RY/BY pin is driven low after the rising edge of the fourth write pulse. During an erase operation, the RY/BY pin is driven low after the rising edge of the sixth write pulse. The RY/BY pin will indicate a busy condition during the RESET pulse. Refer to Figure 11 and 12 for a detailed timing diagram. The RY/BY pin is pulled high in standby mode. Since this is an open-drain output, RY/BY pins can be tied together in parallel with a pull-up resistor to VCC.
RESET Hardware Reset
The MBM29LV008TA/BA devices may be reset by driving the RESET pin to VIL. The RESET pin has a pulse requirement and has to be kept low (VIL) for at least 500 ns in order to properly reset the internal state machine. Any operation in the process of being executed will be terminated and the internal state machine will be reset to the read mode 20 s after the RESET pin is driven low. Furthermore, once the RESET pin goes high, the devices require an additional tRH before it will allow read access. When the RESET pin is low, the devices will be in the standby mode for the duration of the pulse and all the data output pins will be tri-stated. If a hardware reset occurs during a program or erase operation, the data at that particular location will be corrupted. Please note that the RY/BY output signal should be ignored during the RESET pulse. See Figure 12 for the timing diagram. Refer to Temporary Sector Unprotection for additional functionality. If hardware reset occurs during Embedded Erase Algorithm, there is a possibility that the erasing sector(s) cannot be used.
23
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
Data Protection
The MBM29LV008TA/BA are designed to offer protection against accidental erasure or programming caused by spurious system level signals that may exist during power transitions. During power up the devices automatically reset the internal state machine in the Read mode. Also, with its control register architecture, alteration of the memory contents only occurs after successful completion of specific multi-bus cycle command sequences. The devices also incorporate several features to prevent inadvertent write cycles resulting form VCC power-up and power-down transitions or system noise.
Low VCC Write Inhibit
To avoid initiation of a write cycle during VCC power-up and power-down, a write cycle is locked out for VCC less than 2.3 V (typically 2.4 V). If VCC < VLKO, the command register is disabled and all internal program/erase circuits are disabled. Under this condition the device will reset to the read mode. Subsequent writes will be ignored until the VCC level is greater than VLKO. It is the users responsibility to ensure that the control pins are logically correct to prevent unintentional writes when VCC is above 2.3 V. If Embedded Erase Algorithm is interrupted, there is possibility that the erasing sector(s) cannot be used.
Write Pulse "Glitch" Protection
Noise pulses of less than 5 ns (typical) on OE, CE, or WE will not initiate a write cycle.
Logical Inhibit
Writing is inhibited by holding any one of OE = VIL, CE = VIH, or WE = VIH. To initiate a write cycle CE and WE must be a logical zero while OE is a logical one.
Power-Up Write Inhibit
Power-up of the devices with WE = CE = VIL and OE = VIH will not accept commands on the rising edge of write pulse. The internal state machine is automatically reset to the read mode on power-up.
24
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
s ABSOLUTE MAXIMUM RATINGS
Storage Temperature .................................................................................................. -55C to +125C Ambient Temperature with Power Applied .................................................................. -40C to +85C Voltage with respect to Ground All pins except A9, OE and RESET (Note 1) ............. -0.5 V to VCC+0.5 V VCC (Note 1) ................................................................................................................ -0.5 V to +5.5 V A9, OE, and RESET (Note 2) ...................................................................................... -0.5 V to +13.0 V Notes: 1. Minimum DC voltage on input or I/O pins are -0.5 V. During voltage transitions, inputs may negative overshoot VSS to -2.0 V for periods of up to 20 ns. Maximum DC voltage on output and I/O pins are VCC +0.5 V. During voltage transitions, outputs may positive overshoot to VCC +2.0 V for periods of up to 20 ns. 2. Minimum DC input voltage on A9, OE and RESET pins are -0.5 V. During voltage transitions, A9, OE and RESET pins may negative overshoot VSS to -2.0 V for periods of up to 20 ns. Maximum DC input voltage on A9, OE and RESET pins are +13.0 V which may positive overshoot to 14.0 V for periods of up to 20 ns. Voltage difference between input voltage and supply voltage (VIN - VCC) do not exceed 9 V. WARNING: Semiconductor devices can be permanently damaged by application of stress (voltage, current, temperature, etc.) in excess of absolute maximum ratings. Do not exceed these ratings.
s RECOMMENDED OPERATING RANGES
Ambient Temperature (TA) ................................................................. -40C to +85C VCC Supply Voltages MBM29LV008TA/BA-70.................................................................. +3.0 V to +3.6 V MBM29LV008TA/BA-90/-12 ........................................................... +2.7 V to +3.6 V Operating ranges define those limits between which the functionality of the devices are guaranteed. WARNING: The recommended operating conditions are required in order to ensure the normal operation of ranges for the semiconductor device. All of the device's electrical characteristics are warranted when the device is operated within these ranges. Always use semiconductor devices within their recommended operating condition ranges. Operation outside these ranges may adversely affect reliability and could result in device failure. No warranty is made with respect to uses, operating conditions, or combinations not represented on the data sheet. Users considering application outside the listed conditions are advised to contact their FUJITSU representatives beforehand.
25
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
s MAXIMUM OVERSHOOT
+0.6 V -0.5 V -2.0 V
20 ns
20 ns
20 ns
Figure 1
Maximum Negative Overshoot Waveform
20 ns
V CC +2.0 V V CC +0.5 V +2.0 V
20 ns 20 ns
Figure 2
Maximum Positive Overshoot Waveform 1
20 ns
+14.0 V +13.0 V V CC +0.5 V
20 ns 20 ns
*: This waveform is applied for A9, OE, and RESET.
Figure 3
Maximum Positive Overshoot Waveform 2
26
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
s DC CHARACTERISTICS
Parameter Symbol ILI ILO ILIT ICC1 ICC2 ICC3 ICC4 Parameter Description Input Leakage Current Output Leakage Current A9, OE, RESET Inputs Leakage Current VCC Active Current (Note 1) CE = VIL, OE = VIH, f=5 MHz VCC Active Current (Note 2) VCC Current (Standby) VCC Current (Standby, Reset) CE = VIL, OE = VIH VCC = VCC Max., CE = VCC 0.3 V, RESET = VCC 0.3 V VCC = VCC Max., RESET = VSS 0.3 V -- -- -- -- 12 35 5 5 mA mA A A Test Conditions VIN = VSS to VCC, VCC = VCC Max. VOUT = VSS to VCC, VCC = VCC Max. VCC = VCC Max. A9, OE, RESET = 12.5 V CE = VIL, OE = VIH, f=10 MHz Min. -1.0 -1.0 -- -- Max. +1.0 +1.0 35 22 Unit A A A mA
ICC5 VIL VIH
VCC = VCC Max., CE = VSS 0.3 V, VCC Current RESET = VCC 0.3 V (Automatic Sleep Mode) (Note 3) VIN = VCC 0.3 V or VSS 0.3 V Input Low Level Input High Level Voltage for Autoselect, Sector Protection,and Temporary Sector Unprotection (A9, OE, RESET) (Note 4) Output Low Voltage Level Output High Voltage Level -- --
-- -0.5 2.0
5 0.6 VCC + 0.3
A V V
VID
--
11.5
12.5
V
VOL VOH1 VOH2 VLKO Notes: 1. 2. 3. 4.
IOL = 4.0 mA, VCC = VCC Min. IOH = -2.0 mA, VCC = VCC Min. IOH = -100 A --
-- 2.4 VCC - 0.4 2.3
0.45 -- -- 2.5
V V V V
Low VCC Lock-Out Voltage
The ICC current listed includes both the DC operating current and the frequency dependent component. ICC active while Embedded Algorithm (program or erase) is in progress. Automatic sleep mode enables the low power mode when address remain stable for 150 ns. (VID - VCC) do not exceed 9 V.
27
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
s AC CHARACTERISTICS
* Read Only Operations Characteristics Parameter Symbols JEDEC tAVAV tAVQV tELQV tGLQV tEHQZ tGHQZ tAXQX -- Standard tRC tACC tCE tOE tDF tDF tOH tREADY Read Cycle Time Address to Output Delay Chip Enable to Output Delay Output Enable to Output Delay Chip Enable to Output High-Z Output Enable to Output High-Z Output Hold Time From Addresses, CE or OE, Whichever Occurs First RESET Pin Low to Read Mode -- Min. 70 70 70 30 25 25 0 20 90 90 90 35 30 30 0 20 120 120 120 50 30 30 0 20 ns ns ns ns ns ns ns s -70 (Note) -90 (Note) -12 (Note)
Description
Test Setup
Unit
CE = VIL Max. OE = VIL OE = VIL Max. -- -- -- -- -- Max. Max. Max. Min. Max.
Note: Test Conditions: Output Load: 1 TTL gate and 30 pF (MBM29LV008TA/BA-70) 1 TTL gate and 100 pF (MBM29LV008TA/BA-90/-12) Input rise and fall times: 5 ns Input pulse levels: 0.0 V to 3.0 V Timing measurement reference level Input: 1.5 V Output:1.5 V
3.3 V IN3064 or Equivalent Device Under Test 6.2 k CL Diodes = IN3064 or Equivalent
2.7 k
Notes: CL = 30 pF including jig capacitance (MBM29LV008TA/BA-70) CL = 100 pF including jig capacitance (MBM29LV008TA/BA-90/-12)
Figure 4
Test Conditions
28
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
* Write/Erase/Program Operations Parameter Symbols Description JEDEC tAVAV tAVWL tWLAX tDVWH tWHDX -- -- tGHWL tGHEL tELWL tWLEL tWHEH tEHWH tWLWH tELEH tWHWL tEHEL tWHWH1 tWHWH2 -- -- -- -- -- -- -- -- -- Standard tWC tAS tAH tDS tDH tOES tOEH tGHWL tGHEL tCS tWS tCH tWH tWP tCP tWPH tCPH tWHWH1 tWHWH2 tVCS tVIDR tVLHT tWPP tOESP tCSP tRB tRP tRH Write Cycle Time Address Setup Time Address Hold Time Data Setup Time Data Hold Time Output Enable Setup Time Output Enable Hold Time Read Toggle and Data Polling Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Typ. Typ. Min. Min. Min. Min. Min. Min. Min. Min. Min. -70 70 0 45 35 0 0 0 10 0 0 0 0 0 0 35 35 25 25 8 1 50 500 4 100 4 4 0 500 200 -90 90 0 45 45 0 0 0 10 0 0 0 0 0 0 45 45 25 25 8 1 50 500 4 100 4 4 0 500 200 -12 120 0 50 50 0 0 0 10 0 0 0 0 0 0 50 50 30 30 8 1 50 500 4 100 4 4 0 500 200 ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns s sec s ns s s s s ns ns ns MBM29LV008TA/BA Unit
Read Recover Time Before Write Read Recover Time Before Write CE Setup Time WE Setup Time CE Hold Time WE Hold Time Write Pulse Width CE Pulse Width Write Pulse Width High CE Pulse Width High Byte Programming Operation Sector Erase Operation (Note 1) VCC Setup Time Rise Time to VID (Note 2) Voltage Transition Time (Note 2) Write Pulse Width (Note 2) OE Setup Time to WE Active (Note 2) CE Setup Time to WE Active (Note 2) Recover Time From RY/BY RESET Pulse Width RESET Hold Time Before Read
(Continued)
29
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
(Continued)
Parameter Symbols Description JEDEC -- -- Standard tBUSY tEOE Program/Erase Valid to RY/BY Delay
Delay Time from Embedded Output Enable
MBM29LV008TA/BA Unit -70 Max. Max. 90 30 -90 90 35 -12 90 50 ns ns
Notes: 1. This does not include the preprogramming time. 2. This timing is for Sector Protection operation.
30
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
s SWITCHING WAVEFORMS
* Key to Switching Waveforms
WAVEFORM
INPUTS Must Be Steady May Change from H to L May Change from L to H "H" or "L" Any Change Permitted Does Not Apply
OUTPUTS Will Be Steady Will Be Changing from H to L Will Be Changing from L to H Changing State Unknown Center Line is HighImpedance "Off" State
t RC
Addresses
Addresses Stable
t ACC
CE
t OE t DF
OE
t OEH
WE
t CE
Outputs
High-Z
Output Valid
High-Z
Figure 5.1
AC Waveforms for Read Operations
31
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
t RC
Addresses
t ACC t RH
Addresses Stable
RESET
t OH
Outputs
High-Z
Output Valid
Figure 5.2
AC Waveforms for Hardware Reset/Read Operations
32
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
3rd Bus Cycle Addresses
555H t WC PA t AS t AH
Data Polling
PA t RC
CE
t CS t CH t CE
OE
t GHWL t WP t WPH t WHWH1 t OE
WE
t DS t DH t OH
Data
A0H
PD
DQ 7
D OUT
D OUT
Notes: 1. 2. 3. 4. 5.
PA is address of the memory location to be programmed. PD is data to be programmed at byte address. DQ7 is the output of the complement of the data written to the device. DOUT is the output of the data written to the device. Figure indicates last two bus cycles out of four bus cycle sequence.
Figure 6
AC Waveforms for Alternate WE Controlled Program Operations
33
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
3rd Bus Cycle
Data Polling PA t AS t AH PA
Addresses
555H t WC
WE
t WS t WH
OE
t GHEL t CP t CPH t WHWH1
CE
t DS t DH
Data
A0H
PD
DQ 7
D OUT
Notes: 1. 2. 3. 4. 5.
PA is address of the memory location to be programmed. PD is data to be programmed at byte address. DQ7 is the output of the complement of the data written to the device. DOUT is the output of the data written to the device. Figure indicates last two bus cycles out of four bus cycle sequence.
Figure 7
AC Waveforms for Alternate CE Controlled Program Operations
34
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
Addresses
555H t WC
2AAH t AS t AH
555H
555H
2AAH
SA*
CE
t CS t CH
OE
t GHWL t WP t WPH
WE
t DS AAH
t DH 55H 80H AAH 55H 10H/ 30H
Data
t VCS
V CC
* : SA is the sector address for Sector Erase. Addresses = 555H (Word), AAAH (Byte) for Chip Erase.
Figure 8
AC Waveforms Chip/Sector Erase Operations
35
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
CE
t CH
t OE
t DF
OE
t OEH
WE
t CE
* DQ7
Data DQ7 DQ7 = Valid Data High-Z
t WHWH1 or 2
DQ0 to DQ6
Data
DQ0 to DQ6 = Output Flag t EOE
DQ0 to DQ6 Valid Data
High-Z
* : DQ7 = Valid Data (The device has completed the Embedded operation.) Figure 9 AC Waveforms for Data Polling during Embedded Algorithm Operations
CE
tOEH
WE
tOES
OE
*
DQ 6
Data
DQ 6 = Toggle
DQ 6 = Toggle
tOE
DQ 6 = Stop Toggling
Valid
* : DQ6 stops toggling. (The device has completed the Embedded operation.) Figure 10 AC Waveforms for Toggle Bit I during Embedded Algorithm Operations
36
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
CE
The rising edge of the last WE signal
WE
Entire programming or erase operations
RY/BY
t BUSY
Figure 11
RY/BY Timing Diagram during Program/Erase Operations
WE
RESET
tRP t RB
RY/BY
tREADY
Figure 12
RESET/RY/BY Timing Diagram
37
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
A19, A18, A17 A16, A15 A14, A13 A0
SAX
SAY
A1
A6
12 V 3V A9
t VLHT
12 V 3V OE
t VLHT t WPP t VLHT t VLHT
WE
t OESP
CE
t CSP
Data
t VCS t OE
01H
VCC
SAX : Sector Address for initial sector SAY : Sector Address for next sector Figure 13 AC Waveforms for Sector Protection Timing Diagram
38
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
VCC tVCS VID 3V RESET CE
tVIDR tVLHT
3V
WE
tVLHT RY/BY
Program or Erase Command Sequence
tVLHT
Unprotection period
Figure 14
Temporary Sector Unprotection Timing Diagram
Enter Embedded Erasing WE
Erase Suspend Erase
Enter Erase Suspend Program Erase Suspend Program
Erase Resume Erase Suspend Read Erase Erase Complete
Erase Suspend Read
DQ6
DQ2 Toggle DQ2 and DQ6 with OE
Note: DQ2 is read from the erase-suspended sector.
Figure 15
DQ2 vs. DQ6
39
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
VCC
tVCS
RESET tVIDR Add
tVLHT
SPAX
SPAX
SPAY
A0
A1
A6
CE
OE TIME-OUT
WE
Data
60H
60H
40H tOE
01H
60H
SPAX : Sector Address to be protected SPAY : Next Sector Address to be protected TIME-OUT : Time-Out window = 150 s (min) Figure 16 Extended Sector Protection Timing Diagram
40
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
EMBEDDED ALGORITHMS
Start
Write Program Command Sequence (See below)
Data Polling Device
Increment Address
No
Last Address ? Yes
Programming Completed
Program Command Sequence (Address/Command):
555H/AAH
2AAH/55H
555H/A0H
Program Address/Program Data
Figure 17
Embedded ProgramTM Algorithm
41
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
EMBEDDED ALGORITHMS
Start
Write Erase Command Sequece (See below) Data Polling or Toggle Bit Successfully Completed
Erasure Completed Individual Sector/Multiple Sector Erase Command Sequence (Address/Command): 555H/AAH
Chip Erase Command Sequence (Address/Command): 555H/AAH
2AAH/55H
2AAH/55H
555H/80H
555H/80H
555H/AAH
555H/AAH
2AAH/55H
2AAH/55H
555H/10H
Sector Address/30H
Sector Address/30H
Additional sector erase commands are optional.
Sector Address/30H
Figure 18
Embedded EraseTM Algorithm
42
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
Start
Read (DQ 0 to DQ 7) Addr. = VA
DQ 7 = Data? No No DQ 5 = 1? Yes Read (DQ 0 to DQ 7) Addr. = VA
Yes
VA = Address for programming = Any of the sector addresses within the sector being erased during sector erase or multiple erases operation. = Any of the sector addresses within the sector not being protected during sector erase or multiple sector erases operation.
DQ 7 = Data? No Fail
Yes
Pass
Note: DQ7 is rechecked even if DQ5 = "1" because DQ7 may change simultaneously with DQ5.
Figure 19
Data Polling Algorithm
43
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
Start
Read (DQ 0 to DQ 7) Addr. = "H" or "L"
DQ 6 = Toggle ? Yes No DQ 5 = 1? Yes Read (DQ 0 to DQ 7) Addr. = "H" or "L"
No
DQ 6 = Toggle ? Yes Fail
No
Pass
Note: DQ6 is rechecked even if DQ5 = "1" because DQ6 may stop toggling at the same time as DQ5 changing to "1" .
Figure 20
Toggle Bit Algorithm
44
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
Start
Setup Sector Addr. (A19, A18, A17, A16, A15, A14, A13)
PLSCNT = 1
OE = V ID, A 9 = V ID, A 6 = CE = V IL, RESET = V IH A 0 = V IL, A 1 = V IH Activate WE Pulse
Increment PLSCNT
Time out 100 s
WE = V IH, CE = OE = V IL (A 9 should remain V ID)
Read from Sector (Addr. = SA, A 0 = V IL, A 1 = V IH, A 6 = V IL)* No No PLSCNT = 25? Yes Remove V ID from A 9 Write Reset Command Data = 01H? Yes Yes Protect Another Sector? No Device Failed Remove V ID from A 9 Write Reset Command
Sector Protection Completed
Figure 21
Sector Protection Algorithm
45
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
Start
RESET = VID (Note 1)
Perform Erase or Program Operations
RESET = VIH
Temporary Sector Unprotection Completed (Note 2)
Notes: 1. All protected sectors are unprotected. 2. All previously protected sectors are protected once again.
Figure 22
Temporary Sector Unprotection Algorithm
46
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
FAST MODE ALGORITHM
Start
RESET = VID
Wait to 4 s
Device is Operating in Temporary Sector Unprotection Mode
No
Extended Sector Protection Entry? Yes To Setup Sector Protection Write XXXH/60H
PLSCNT = 1
To Sector Protection Write SPA/60H (A0 = VIL, A1 = VIH, A6 = VIL)
Increment PLSCNT
Time Out 150 s
To Verify Sector Protection Write SPA/40H (A0 = VIL, A1 = VIH, A6 = VIL)
Setup Next Sector Address
Read from Sector Address (A0 = VIL, A1 = VIH, A6 = VIL) No No PLSCNT = 25? Yes Remove VID from RESET Write Reset Command Data = 01H? Yes Protection Other Sector ? No Remove VID from RESET Write Reset Command Yes
Device Failed
Sector Protection Completed
Figure 23
Extended Sector Protection Algorithm
47
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
FAST MODE ALGORITHM
Start
555H/AAH
2AAH/55H
Set Fast Mode
555H/20H
XXXH/A0H
Program Address/Program Data
Data Polling Device
Verify Byte? Yes No
No
In Fast Program
Increment Address
Last Address ? Yes Programming Completed
XXXH/90H Reset Fast Mode XXXH/F0H
Figure 24
Embedded ProgramTM Algorithm for Fast Mode
48
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
s ERASE AND PROGRAMMING PERFORMANCE
Limits Parameter Min. Sector Erase Time Byte Programming Time Chip Programming Time Erase/Program Cycle -- -- -- 100,000 Typ. 1 8 8.4 -- Max. 10 300 25 -- sec s sec cycles Excludes programming time prior to erasure Excludes system-level overhead Excludes system-level overhead -- Unit Comments
s TSOP(I) PIN CAPACITANCE
Parameter Symbol CIN COUT CIN2 Parameter Description Input Capacitance Output Capacitance Control Pin Capacitance Test Setup VIN = 0 VOUT = 0 VIN = 0 Typ. 7 8 10 Max. 10 10 12 Unit pF pF pF
Note: Test conditions TA = 25C, f = 1.0 MHz
49
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
s PACKAGE DIMENSIONS
40-pin plastic TSOP(I) (FPT-40P-M06)
LEAD No.
1 40
Details of "A" part 0.15(.006) MAX 0.35(.014) MAX
INDEX "A"
0.15(.006)
20 21
0.25(.010)
0.150.05 (.006.002) 20.000.20 (.787.008) 18.400.20 (.724.008) 0.50(.0197) TYP 0.500.10 (.020.004) 10.000.20 (.394.008)
0.05(.002)MIN (STAND OFF) 1.10 -0.05 .043 -.002
(Mounting height)
+0.10 +.004
0.10(.004) 19.000.20 (.748.008)
9.50(.374) REF. 0.200.10 0.10(.004) (.008.004)
M
C
1994 FUJITSU LIMITED F40007S-1C-1
Dimensions in mm (inches)
40-pin plastic TSOP(I) (FPT-40P-M07)
LEAD No.
1 40
Details of "A" part 0.15(.006) MAX 0.35(.014) MAX
INDEX
"A"
0.15(.006)
20 21
0.25(.010)
19.000.20 (.748.008) 0.150.05 (.006.002) 0.10(.004)
0.500.10 (.020.004) 0.50(.0197) TYP
0.200.10 (.008.004)
0.10(.004)
M
9.50(.374) REF.
0.05(.002)MIN (STAND OFF)
18.400.20 (.724.008) 20.000.20 (.787.008)
1.10 -0.05 .043 -.002 10.000.20 (.394.008)
(Mounting height)
+0.10
+.004
C
1994 FUJITSU LIMITED F40008S-1C-1
Dimensions in mm (inches)
50
To Top / Lineup / Index
MBM29LV008TA-70/-90/-12/MBM29LV008BA-70/-90/-12
FUJITSU LIMITED
For further information please contact:
Japan FUJITSU LIMITED Corporate Global Business Support Division Electronic Devices KAWASAKI PLANT, 4-1-1, Kamikodanaka Nakahara-ku, Kawasaki-shi Kanagawa 211-8588, Japan Tel: 81(44) 754-3763 Fax: 81(44) 754-3329
All Rights Reserved. The contents of this document are subject to change without notice. Customers are advised to consult with FUJITSU sales representatives before ordering. The information and circuit diagrams in this document are presented as examples of semiconductor device applications, and are not intended to be incorporated in devices for actual use. Also, FUJITSU is unable to assume responsibility for infringement of any patent rights or other rights of third parties arising from the use of this information or circuit diagrams. FUJITSU semiconductor devices are intended for use in standard applications (computers, office automation and other office equipment, industrial, communications, and measurement equipment, personal or household devices, etc.). CAUTION: Customers considering the use of our products in special applications where failure or abnormal operation may directly affect human lives or cause physical injury or property damage, or where extremely high levels of reliability are demanded (such as aerospace systems, atomic energy controls, sea floor repeaters, vehicle operating controls, medical devices for life support, etc.) are requested to consult with FUJITSU sales representatives before such use. The company will not be responsible for damages arising from such use without prior approval. Any semiconductor devices have an inhereut chance of failure. You must protect against injury, damage or loss from such failures by incorporating safety design measures into your facility and equipment such as redundancy, fire protection, and prevention of over-current levels and other abnormal operating conditions. If any products described in this document represent goods or technologies subject to certain restrictions on export under the Foreign Exchange and Foreign Trade Law of Japan, the prior authorization by Japanese government will be required for export of those products from Japan.
http://www.fujitsu.co.jp/
North and South America FUJITSU MICROELECTRONICS, INC. Semiconductor Division 3545 North First Street San Jose, CA 95134-1804, USA Tel: (408) 922-9000 Fax: (408) 922-9179 Customer Response Center Mon. - Fri.: 7 am - 5 pm (PST) Tel: (800) 866-8608 Fax: (408) 922-9179
http://www.fujitsumicro.com/
Europe FUJITSU MIKROELEKTRONIK GmbH Am Siebenstein 6-10 D-63303 Dreieich-Buchschlag Germany Tel: (06103) 690-0 Fax: (06103) 690-122
http://www.fujitsu-ede.com/
Asia Pacific FUJITSU MICROELECTRONICS ASIA PTE LTD #05-08, 151 Lorong Chuan New Tech Park Singapore 556741 Tel: (65) 281-0770 Fax: (65) 281-0220
http://www.fmap.com.sg/
F9904 (c) FUJITSU LIMITED Printed in Japan
51


▲Up To Search▲   

 
Price & Availability of MBM29LV008BA-12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X